2022 Caterpillar Generator Set Control Panels EMCP 4.1 Control Panel

2022 Caterpillar Generator Set Control Panels EMCP 4.1 Control Panel

Swipe to View More

  • Year 2022
  • Make Caterpillar
  • Model Generator Set Control Panels
2022 Caterpillar Generator Set Control Panels EMCP 4.1 Control Panel

2022 Caterpillar Generator Set Control Panels EMCP 4.1 Control Panel

2022 Caterpillar Generator Set Control Panels EMCP 4.4 Control Panel

The EMCP 4 Control Panel provides all of the controls and system indicators in one easy to access interface.

Features may include:

EMCP 4 CONTROLS
  • The EMCP 4 includes the following controls:
  • Auto / Start / Stop Control
  • Speed and Voltage Adjust
  • Engine Cycle Crank
  • Programmable Cycle Timer
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm/event descriptions
  • Paralleling Mutiple Generator Set or Single Generator Set to Single Utility
  • Remote start / stop
  • Engine Cooldown Timer
  • Local and remote emergency stop
Digital indicators
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N), frequency (Hz)
  • Amps (per phase & average)
  • ekW, kVA, kVAR, kW-hr, %kW, PF
  • Battery voltage
  • Oil Temperature
  • Multiple Language Support
  • Crank attempt and successful start counter
  • Run hours
Warning / shutdown indicators
  • The EMCP 4 has common LED indicators of the following warning and shutdown conditions
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Low engine oil pressure (alarm)
  • High engine oil temp (alarm and shutdown)
  • High coolant temp (alarm and shutdown)
  • Low coolant temp (alarm)
  • Low coolant level (alarm)
  • Control switch not in auto (alarm)
  • Low, high, and weak battery voltage
Programmable protective relaying
  • Generator phase sequence
  • Over/Under voltage (27/59)
  • Over/Under Frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Overcurrent Thermal Damage Curve
  • Current Balance (46)
  • Bus Phase Sequence
  • Over/Under frequency (81/OU)
Communications
  • Twelve digital inputs
  • Emergency stop pushbutton
  • Five Analog output
  • Seventeen digital outputs
  • Two Analog Input
  • customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • Ethernet SCADA (Modbus TCP)
Compatibility
  • The EMCP 4 is compatible with:
  • Remote CAN annunciator
  • Remote serial annunciator
  • Local Annunciator
  • Remote Monitoring Software
  • Digital I/O module
  • RTD module
  • Thermocouple module
  • Supervisory Control Panel
  • Master Control Panel
Display
  • a 33 x 132 pixel, 3.8 inch, graphical display denotes text alarm/event descriptions, set points, engine and generator monitoring and is visible in all lighting conditions
Generator monitoring
  • voltage (l-l, l-n)
  • current (phase)
  • average volt, amp, frequency